Geotechnical Testing Equipment
The Best In Test
![]() |
Fineness, Blaine Air Apparatus Standards: EN 196-6, 459-2, 13286-44, BS 4359-2, ASTM C204 The Blaine Air Apparatus is used to determine the particle size of Comprises: It comprises of a stainless steel cell, perforated disc and plunger. A U-tube glass manometer is fitted to the steel stand. The set is complete with rubber aspirator and filter paper. |
|
|
Cement Flow Table Standards: BS 4551-1, 3892-1, EN 459-2, 1015-3, 1015-9, The Flow Table is used for determining consistency of mortar, lime and cement specimens. The table is 300mm dia., 10mm drop height. The cone made of brass has dimensions of 100mm base dia. x 70mm top dia. x 60mm high.
|
![]() |
Automatic Cement Flow Table Standards: ASTM C230 The Automatic Flow Table is used for determining consistency of mortar, lime and cement specimens. The table is 254mm dia., 12,7mm drop height. |
|
|
Standards: BS 6463; EN 196-3, 459-2, EN ISO 9597 Le Chatelier method determines the soundness of cements and limes by using the expansion test with Le chatelier moulds according to the relevant standard. Comprises: The mould consists of a spring tensioned split cylinder 30 mm internal diameter x 30 mm high with two indicator stems which measure 150 mm from the points to the centre line of the cylinder and O-ring. Standard weight 100 g ±10 g and two glass plate are supplied complete with the mould. |
![]() |
Le Chatelier Water Bath Standards: EN 196-3, 459-2 The Chatelier Water Bath is use with Le Chatelier moulds for the determination of the soundness of cement paste. Comprises: The Water Bath comes complete with removable rack to hold twelve moulds and cover. Build in digital Thermostat controller to regulate the water temperature from ambient to boiling point.
|
|
|
Standards: EN 196-6, ASTM C188, AASHTO T133
|
![]() |
Vicat Apparatus
Standards: EN 196-3, 13454-2, ASTM C187, C191, AASHTO T129, T131 The Vicant Apparatus is used for determining setting time and consistency of cement by Vicat Method. Comprises: The test set comprises of Vicat Frame, Vicat Mould, Initial and Final needles, glass plate and consistency plunger.
|
|
|
Automatic Vicat Apparatus Standards: EN 196-3:2005, 13279-2, 480-2, ASTM C187, C191, BS 4550, AASHTO T129, T131 The Automatic Vicat Apparatus is designed and manufactured using the most recent and sophisticated technology, it is used for the initial and final setting time determination of cements The apparatus is manufactured with anticorrosion components to be used in places with humidity up to 90% and 20°C. The entire test is made in a fully automatic way and gives a very precise and repeatable result with controlled temperature as required by EN Specifications. The results are printed on the incorporated printer and this eliminates the manual operations of installing and zeroing the paper graph on the drum.
|
![]() |
Cement Shrinkage Test Standards: EN 1367- 4, EN 12617- 4, ASTM C151, C490, BS 1881:5, 6073 The Cement Shrinkage Test is used to determine the accelerated soundness (autoclave method) and length Comprises: The set comprises of length measuring frame, two or three gang steel mould according to the related standard, steel inserts for moulds and reference rod.
|
|
|
Standards: EN196-21;ASTM C114 |
![]() |
Vibrating Machine Standards: BS 4550 The Vibrating Machine is perfect for the preparation and compaction of 70.7 mm mortar cube specimens. The vibrating shaft of the machine allows each sample to be vibrated at 12000 cycles per minute. Fitted with setting timer the vibrating machine can stop automatically when set time is completed. |
|
|
Heat of Hydration Apparatus Standards: BS 4550, ASTM C186 This Apparatus is required for determining the heat of hydration of cement as expressed in calories per gram. Comprises: A wide mouthed double walled vacuum flask with a cork stopper 38 mm thick and an insulated container for flask. A beckman thermometer held tightly by the cork stopper in such a way as to avoid accidental contact with stirrer blades and a reading lens. To facilitate removal, cork stopper is divided into two halves. |
|
|
Automatic Mortar Mixer Standards: EN 196-1, 196-3, 413-2, 459-2 The Automatic mixer is perfect to mix mortars and cement material according to the required standards. The mixer is very rigid and durable with a planetary motion
|
![]() |
Cement Compression and Flexural Machine Standards: EN 196-1, ASTM C109 Very silent power pack can load a specimen between 1 kN/sec to 20 kN/sec. On the dual stage pump high delivery low pressure pump is used for rapid approach and low delivery On all power packs maximum pressure valve is used to avoid machine overloading. On both frame the load is measured by load cell to get accurate test results. The machine is supplied with safety doors and can test samples up to 250KN.
|
|
|
Humidity Curing Cabinet Standards: BS 3892-1, EN 196-1 459-2 Dimensions: (l x w x h) Internal: 700x900x1300 mm External: 850x1200x1900 mm Weight: 250 kg |
![]() |
Jolting Table Standards: EN 196-1 Jolting table is used for mould compacting of 40.1x40x160 mm cement specimens and consists of mould table seated on a rotating cam driven at 60 revolutions per minute. The Jolting Table is 15.0 mm drop equipped with counter which provides automatic shut off at end of preset drop numbers. Rapid mould lock and release system allows easy and quick operation. |